Calculation4 min readUpdated: 2025-06
In Africa, solar panels frequently operate at ambient temperatures of 35–45°C. Every degree above 25°C (STC reference temperature) loses approximately 0.4% of power on a monocrystalline panel.
T_cell = T_ambient + 25If wind speed > 5 m/s → T_cell -= 5 (wind cooling effect)
Thermal_loss = (T_cell - 25) × 0.0040.4% loss per °C above 25°C · result between 0 and 1
P_final = P_theoretical ÷ (1 - Thermal_loss)P_theoretical = E_req ÷ PSH · PSH = peak sun hours
+15.2%
Bamako, July
38°C, wind 2 m/s → T_cell 63°C
+10.0%
Dakar, January
30°C, wind 7 m/s → T_cell 50°C
+2.4%
Paris, June
22°C, wind 4 m/s → T_cell 47°C
SolarDim Pro applies this correction automatically. An engineer calculating without thermal correction will undersize the PV array by 10–15% in Sahelian cities.
Common mistakes
- Sizing the PV array with a fixed PR (0.80) without adjusting for site temperature
- Ignoring the wind-cooling effect, which overestimates thermal loss
- Using average annual ambient temperature instead of peak (hot season) temperature