Help CenterPV Calculations

Depth of Discharge (DoD) by battery technology

Calculation3 min readUpdated: 2025-06

Depth of Discharge (DoD) is the maximum percentage of nominal capacity that should be discharged. Regularly exceeding this threshold dramatically reduces battery lifespan.

SolarDim Pro auto-updates DoD when you change battery technology. Never manually enter 80% for a Gel battery — it would reduce its lifespan by 70%.

TechnologyRecommended DoDCycles (at nominal DoD)African context
LiFePO480%3,000–6,000Recommended > 2 kWh, high temperatures
AGM Lead-Acid50%300–500Economic backup, temperate zones
Gel Lead-Acid50%400–600Handles heat better than AGM
Flooded Lead50%200–350Tight budget only, requires maintenance
C_Ah = (E_Wh × autonomy_days) ÷ (V_sys × DoD)

E_Wh = daily consumption · V_sys = system voltage · DoD = depth of discharge

3,450 Wh

Daily consumption

2 days autonomy

359 Ah

LiFePO4 (80% DoD)

8.6 kWh nominal

575 Ah

Gel (50% DoD)

13.8 kWh nominal

For sub-Saharan Africa with temperatures > 35°C, SolarDim Pro recommends LiFePO4 for any system > 2 kWh. The higher upfront cost is offset by longer lifespan (10 years vs 3–4 for Gel).

Common mistakes

  • Entering 80% DoD for a Gel/AGM battery "because it worked with lithium"
  • Ignoring ambient temperature > 35°C, which accelerates lead-acid battery aging
  • Comparing only purchase price instead of total cost (cycles × capacity) across technologies